Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency phone not dialing out
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Machine room has inadequate lighting
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Machine room needs fire extinguisher
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No Machine room oil pan full. Clean and repair leaks on pump ,valve or muffler.
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door must be self-closing and self-locking 3/25/2026
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Oil overflowed pan. Clean pan and floor 3/25/2026
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Machine room lighting below standard 3/25/2026
MO Minimum : Elevators (I) - Pits (I)1 No No Pit needs cleaning from oil bucket overflowed because of excessive packing leakage 3/25/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No The hydraulic pump, valve and/muffler leaking. Repair with seals and/or tighten all fittings and bolts 3/25/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Fire extinguisher out of date 3/25/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance No No Excessive packing leakage. Replace 3/25/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No The Hydraulic pump unit seals appears to be leaking as well as the unit muffler bolts. This is creating an overflow of the pump oil containment pan. 3/25/2026