Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance Excessive packing leakage. Replace
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher out of date
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door must be self-closing and self-locking
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room lighting below standard
MO Minimum : Elevators (H) - Machine Rooms (H)4 Oil overflowed pan. Clean pan and floor
MO Minimum : Elevators (I) - Pits (I)1 Pit needs cleaning from oil bucket overflowed because of excessive packing leakage
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection The Hydraulic pump unit seals appears to be leaking as well as the unit muffler bolts. This is creating an overflow of the pump oil containment pan.