Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Provide monthly fire service testing of fire service and document on log in machine room 1/14/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need maintenance control program on site posted on controller 10/27/2020
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 7/19/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(2) A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. 7/19/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(d)(1) Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. 7/19/2024
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 6/24/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up to date operating certificate required in the elevator machine room. 6/24/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Emergency power operation of the elevator shall be tested. 5/24/2024
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Runby (Re-Inspect) x Hoist ropes have stretched and the counterweight is compressing the buffer. 7/20/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Emergency power operation of the elevator needs to be tested. 11/21/2023
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Test emergency power. Elevator did not work per code requirements. 7/20/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation x A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/11/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4.1(c)(2) x A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. 8/11/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(d)(1) x Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. 8/11/2021
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.3 x Where elevator equipment is located or its enclosure is configured such that application of water from sprinklers could cause unsafe elevator operation, means shall be provided to automatically disconnect the main line power supply to the affected elevator and any other power supplies used to move the elevator upon or prior to the application of water. 8/11/2021
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Emergency/standby power operation of the elevator shall be tested. 8/11/2021
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 x All live parts of electrical apparatus in the hoistway and the machine room shall be enclosed. 8/11/2021
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 2.8.2 x Lighting in the machine room shall be not less than ten (10) foot-candles at floor level. 8/11/2021
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Replace hoist ropes (red rouge (reduced diameter) 1/14/2020