Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Pit scavenger pump will be removed or routed to a measurable container. 8/31/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency/auxiliary lighting shall work with power loss. Unusually dim, 7/2/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation G(1)/8.6.1.6 : MCP shall be kept in equipment room, including Oil loss log and Fire service testing log, recorded monthly. None onsite. 8/31/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Pit scavenger pump will be removed or routed to a measurable container. 7/2/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency/auxiliary lighting shall work with power loss. Unusually dim, 7/2/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation G(1)/8.6.1.6 : MCP shall be kept in equipment room, including Oil loss log and Fire service testing log, recorded monthly. None onsite. per gregg 7/2/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records G(1)/A17.1-2016:8.6.1.4 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) . 8/31/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Door Systems x 3.17.1 (6)(b)(1). Fire tabs on Hoistway and car doors required to engage sill. 7/2/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Door Systems x 3.17.1 (6)(b)(1). Fire tabs on Hoistway and car doors required to engage sill. 7/2/2021