Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Car door and hoistway doors are dragging against sills and will not open fully adjust doors 9/3/2019
conversion conversion n/a No No Elevator pit full of water clean elevator pit 9/3/2019
conversion conversion n/a No No Replace missing hoistway door pickup rollers. 9/3/2019
MO Minimum : Elevators (I) - Pits (I)1 No No Pit light inoperative. Repair. 9/3/2019
MO Minimum : Elevators (I) - Pits (I)1 No No Remove standing water from pit. 9/3/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Car top light inoperative. Repair. 9/3/2019
MO Minimum : Elevators (A) - Hoistways (A)14 No No Repair hole in hoistway shaft liner, second landing. 9/3/2019
MO Minimum : Elevators (I) - Pits (I)1 No No Remove standing water in pit. 9/9/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Pit light inoperative. 9/9/2020
MO Minimum : Elevators (A) - Hoistways (A)14 No No Repair hole in hoistway shaft liner. Second floor. 9/9/2020
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)6 No No Replace worn out guide shoes on elevator car top 11/18/2025
MO Minimum : Elevators (I) - Pits (I)1 No No Clean elevator pit from oil & debris 11/18/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Clean dirt from elevator car top 11/18/2025
MO Minimum : Elevators (A) - Hoistways (A)3 No No When hoistway doors are closed and in the locked position, the hoistway doors at the furthest point from the interlock can be opened 2 1/2 inches. Adjust / repair doors to open a maximum of 1 inch. 11/18/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Need to clean dirt from elevator car top 11/18/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Alarm bell in elevator cab does not work on battery backup power, needs repaired. Re-inspection required 11/18/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency light inoperative. 10/30/2020
MO Minimum : Elevators (F) - Electrical Switches (F)1 Yes No Emergency stop toggle disconnected from alarm bell. 10/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency light inoperative. Repair. 1/24/2020
MO Minimum : Elevators (F) - Electrical Switches (F)1 Yes No Cab emergency stop switch toggle disconnected from alarm bell. 1/24/2020
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Building under renovation. Landing initiating devices (smokes) disconnected and/or removed. Replace, connect, and test all landing initiating devices. 1/24/2020