Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 1/22/2019
MO Minimum : Elevators (H) - Machine Rooms (H)1 Provide a permanent means to access machine room. 1/22/2019
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)6 Post capacity plate and "No Passengers" signage inside elevator cab. 1/22/2019
MO Minimum : Elevators (I) - Pits (I)7 Provide a pit stop switch. 1/22/2019
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide code compliant pit lighting. 1/22/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Adjust the gate switch to prevent the car from running when the car door is open greater than 2". 11/4/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Adjust the top floor door for proper balance. 11/4/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Adjust the top floor door locking bar for proper operation. 11/4/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The reverse phase switch is broken and requires replacement. 7/16/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The in car emergency lighting shall be operational. 7/16/2021
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)6 x x Remove the unwired governor speed switch. Governor speed switch is not required for elevators running less than 150 fpm. - Unit not Red Tagged 7/16/2021
MO Minimum : Elevators (K) - Car Platforms and Car Slings (K)1 There is structural damage under the car frame that shall be repaired. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The electrical box attached to the top of the car needs a cover plate. 9/1/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The lighting in the machine room shall be not less than 10 foot-candles at floor level. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/1/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be obtained and displayed in the elevator machine room. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Install a code data plate. It shall read: "Missouri Minimums" 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/1/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be obtained and displayed in the elevator machine room. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The disconnect located in the machine room shall be provided with a sign to identify the location of the supply side overcurrent protective device. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. 9/1/2021
MO Minimum : Elevators (H) - Machine Rooms (H)8 The four inch electrical box located in the machine room requires a cover. 9/1/2021
MO Minimum : Elevators (I) - Pits (I)1 Clean the pit of dirt and debris. 9/1/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) A permanent lighting fixture shall be provided in all pits to provide an illumination of not less than 5 foot-candles at the pit floor. The fixture switch shall be provided and accessible from the pit access door. 9/1/2021
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)5 Each freight car enclosure shall have lighting not less than two and one-half (2.5) foot-candles. Bulbs or tubes shall be guarded to prevent breakage. 9/1/2021
MO Minimum : Elevators (I) - Pits (I)3 Counterweight guards shall extend from a point not more than 12" above the pit floor to a point not less than 7' above the pit floor. 9/1/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The electrical box attached to the underside of the car needs a cover plate. 9/1/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. 9/8/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. 9/8/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts The vision panel on the first floor does not meet code. The vision panel in the basement is broken. Replace both panels to meet the following code: Ref: A17.1-2016, 2.14.2.5, A17.2, 1.11 9/16/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/19/2022
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room lighting shall be operational. 9/19/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO state operating certificate shall be displayed in the elevator machine room. 9/19/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x x This car has been red tagged. Upon arrival, the button was pushed to call the elevator, the doors opened, and the car was not at the floor. 8/31/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x There is a 3 1/2" gap between the door and the wall; it should be around 1 1/4". 8/31/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Testing is complete. Need to do all of the annual, slide, pull out/pull thru, and governor switch. 8/31/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x There is a 3 1/2" gap between the door and the wall; it should be around 1 1/4". Take corrective action. 8/26/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Testing is incomplete. Need to do all of the annual, slide, pull out/pull thru, and governor switch. 8/26/2024