Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x The governor rope needs to be replaced. (2nd Notice) 11/26/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The governor rope needs to be replaced. 1/17/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts The car stiffeners on both sides of the car need to be replaced. 10/31/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) x Suspension ropes need to be shortened. There is only has 3" of runby. Provide code compliant runby. 2/6/2025
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation Fire service testing must be completed and documented monthly. The form is present in the MCP, but has not been logged monthly.
MO Minimum : Elevators (H) - Machine Rooms (H)2 Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. 10/31/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 10/31/2023