Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Correct cab clearance in hoistway 1/13/2020
conversion conversion n/a Trim cab flooring - trip hazard 1/13/2020
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service test & document on log posted in machine room, 3/25/2021
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Provide Phase 1 Fire Service instructions at the 1st floor & phase 2 fire service instructions in the car 3/25/2021
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator storage from machine room 3/25/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Need testing procedures in the MCP on or before 1/1/22 10/26/2021
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Provide Phase 1 Fire Service instructions at the 1st Floor, Provide Phase 2 Fire Service instructions in car
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service testing and document on log in machine room 11/5/2024
MO Minimum : Elevators (I) - Pits (I)1 Clean Pit 11/5/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Repair pit light
MO Minimum : Elevators (H) - Machine Rooms (H)2 Provide lock for machine room access door
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service and document on log in machine room 11/5/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Repair pit lighting repeat violation
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post phase 1 & 2 fire service instructions at 1st floor & in the car
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 11/5/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 11/5/2024
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service testing and document on log in machine room
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all non elevator storage from the machine room 11/5/2024
MO Minimum : Elevators (I) - Pits (I)1 Remove trash from the pit and excess lint from the rails 11/5/2024