Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a No No Door closing force shall be less than 30# 11/8/2018
conversion conversion n/a No No Failed static test, leaking back through control valve 11/8/2018
conversion conversion conversion - reinspect Yes No Emergency light and bell shall work 8/15/2018
conversion conversion n/a No No Fire stops on hoistway doors are missing 11/8/2018
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) Yes No Car door restrictor does not work. 5/18/2020
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Phase 2 fire service does not work correctly. When at alternate landing and Phase 2 switch is moved from On to Hold, door closes and reverts back to Phase 1. Did not red tag. Reinspect within 30 days. 5/18/2020