MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
x
|
|
8.6.4.12.1 While compressing the car buffer, the elevator strikes the governor tail sheave causing the safeties to engage before the buffer is fully compressed. 2.4.1.5 When the car is resting on its fully compressed buffers or bumpers, no part of the car, or any equipment attached thereto or equipment traveling with the car, shall strike any part of the pit or any equipment mounted therein.
|
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Accumulated oil in pit
|
9/22/2025
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3.2 Phase I Operation Recall by Initiating Device
|
x
|
x
|
All applicable FAID will be tested with all 5 tractions cars online.
|
3/21/2025
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator.
|
|
|
A17.1-2016 : Elevators
|
2.14 - Code data plate
|
8.9
|
x
|
|
Controller code data plate is blank.
|
3/21/2025
|
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
2.27.1.1.6 Verification of Telephone Operability
|
x
|
|
Emergency communication failure detection system shall work.
|
3/21/2025
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
2.27.2
|
x
|
|
Emergency power to be tested with rated load.
|
3/21/2025
|
|
A17.1-2016 : Elevators
|
2.8 - Pipes, wiring, and ducts
|
2.8
|
x
|
|
Machine room 4x4 box shall have wiring inside box and cover installed.
|
3/21/2025
|
|
A17.1-2016 : Elevators
|
2.10 - Numbering of Elevators, Machines, Controllers, and Disconnect Switches
|
2.29.1
|
x
|
|
Machine room machinery, controllers, governors, disconnects, etc. shall have proper numbering.
|
3/21/2025
|
|
A17.1-2016 : Elevators
|
2.3 - Lighting and receptacles
|
2.8.2
|
x
|
|
Machine room outlests to be GFI protected.
|
3/21/2025
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Remove oil from pit floor
|
9/22/2025
|
|
A17.1-2016 : Elevators
|
5.6 - Governor-rope tension devices
|
2.18.7
|
x
|
|
Shorten governor rope to allow proper pit clearance of tail-sheave. Currently only about 1/2" clearance to pit floor.
|
3/21/2025
|