MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
Test phase 1 and 2 fire service. Re-inspection required
|
3/4/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Tried to perform elevator emergency power test, elevator would not run on emergency power. Also ensure that the elevator cab lights are on emergency power. Re-inspection required
|
8/9/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Tried to perform elevator emergency power test. Elevator would not run on emergency power. Also ensure that elevator cab lights are on emergency power. Re-inspection required
|
8/30/2024
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Elevators connected to an emergency generator shall be tested for operation on emergency power. Re-inspection required
|
3/4/2024
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not work.
|
1/5/2022
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
1001.2(d)(12) -
|
|
|
Provide, repair or replace phase II key switch in car.
|
8/28/2019
|