Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x Emergency light and alarm bell not working. 1/31/2020
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log No firefighter's instructions inside of car. 6/23/2021
MO Minimum : Elevators (I) - Pits (I)1 Clean pit of debris. 6/23/2021
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x The Service Elevator Fire Recall shall be keyed like the 2 Modernized Lobby Cars. (FEOK 1 Key) 2/23/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Fire service key must match the two modernized elevators. Re-inspection required 3/3/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone is inoperable. Re-inspection required 3/3/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Bottom directional roller shall be replaced.
conversion conversion n/a No MCP 6/23/2021
conversion conversion n/a No monthly fire test record 6/23/2021
conversion conversion conversion - reinspect x Fire service Phase I & 2 not working 8/15/2019
conversion conversion conversion - reinspect x Alarm Bell and Emergency light not working 8/15/2019