Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance Piston packing is worn and leaking, repair as needed. 12/6/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x While on Phase II, in car stop switch is not overridden. Repair as needed. 7/11/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone rings to 911 - reprogram and retest. 6/18/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency light and alarm bell do not work. 6/18/2021
A17.1-1996 : Elevators 2.32 - Control Valve 1004.2(b)(15) Car failed to maintain floor level on 15 minute stand test, determined to be leaking back through valve. Repair and test. 12/6/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current certificate. 12/6/2023