Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Provide on-site written maintenance control program for each elevator. 12/7/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current certificate. 12/7/2023
A17.1-1996 : Elevators 2.35 - Supply Line and Shutoff Valve 303 Hydraulic fitting under the hydraulic valve appears to be worn and leaking oil on top of the tank. Repair or replace 12/7/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone rings to 911. Reprogram and retest. 6/18/2021
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x OSV is not sealed and noted on last inspection report of 2020. Perform OSV test within 90 days. 7/29/2022