Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.1 - Access to machine space 2.7.3.1 Clearly mark and pad any sharp edges of the air handler outside the machine room door. Potential hazard for personnel entering machine room. Safe and convenient machine room access shall be provided. 1/31/2024
MO Minimum : Elevators (I) - Pits (I)1 The pit shall be kept clean and dry. 12/26/2024
MO Minimum : Elevators (S) - Fire Service (S)1 x x Phase 2 emergency fire service does not work properly. Upon activation of phase 2 key switch, elevator doors close, then trap occupants inside the cab. Fire service shall be repaired and tested. - Unit Red-Tagged 11/13/2018
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)2(D) The relief pressure shall be tested once the fire service issue is resolved and red tag removed. 1/8/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 1/27/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 1/27/2022
MO Minimum : Elevators (A) - Hoistways (A)16 The traveling cables shall be installed using an approved method. 1/27/2022
MO Minimum : Elevators (H) - Machine Rooms (H)4 The concrete debris shall be removed from the machine room floor. 1/27/2022