MO Minimum : Elevators (H) - Machine Rooms (H)2 All machine rooms or enclosures shall have a self-locking door and shall be operable from the interior space without use of a key.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers An ABC fire extinguisher with a current test tag shall be mounted in the machine room located convenient to the access door.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room shall have proper lighting not less than 10 fc at the floor level.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up-to-date operating certificate is required in the machine room.