Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.18 - Restricted opening of car or hoistway doors 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) x A17.1-2004 2.12.5 Restricted Opening of Hoistway or Car Doors 2.12.5.2 When the car doors are so arranged that they cannot be opened when the car is outside the unlocking zone, the car doors shall be openable from outside the car without the use of a special tool(s). CAR DOOR RESTRICTOR BROKEN AND REMOVED FROM DOOR (OTIS) RE-INSPECTION REQUIRED. 9/22/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x A17.1-2004 2.27.1.1 Emergency Communications Car emergency phone shall work. Phone not dialing out, shares line with Fax w/out surrender device. (Caruthersville High School) RE-INSPECTION REQUIRED. 9/22/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation A17.1 - 2016 8.6.1.2.2 MCP ONSITE DOCUMENTATION NEEDED TO FULFILL 8.6.1.1.1(b) & ONSITE MAINTENANCE RECORDS (see 8.6.1.4.1) THAT RECORD THE COMPLETION OF ALL ASSCIATED MAINTENANCE TASKS SPECIFIED IN 8.6.1.4.19(a) NO WRITTEN DOCUMENTATION FOR MAINTENANCE IN MACHINE ROOM OR WHERE TO RETRIVE IT FROM. (OIL USAGE , FIRE SERVICE, MAINTENANCE & CALL BACK LOGS) 8/30/2024