Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 103.2 x Counterweight to buffer Clearence shall be 6 - 16 inches for spring buffers
conversion conversion conversion - reinspect x Car Door restrict or not working 7/23/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Ropes need to be shortened. Do not meet minimum requirements. 12/3/2020
A17.1-1996 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 107.1b x Minimum runby for spring buffers shall be 6in 7/25/2024