Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.17 - Standby power operation 1001.2(a)(17) x Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. 12/7/2021
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed/rupture valve this is not sealed. A category 5 test shall be perform on or before the next annual inspection and the valve sealed. 8/30/2021
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 10/8/2024
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 1001.2(b)(8) Pipes conveying liquid, gas or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. 5/11/2020