Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.4 - Sills and car floor 1001.2(a)(4) No No Fill gap in car flooring at the entrance (tripping hazard) 10/18/2022
A17.1-1996 : Elevators 1.4 - Sills and car floor 1001.2(a)(4) No No Replace missing floor strip on L1 & LD level at access to the car (tripping Hazard) 10/18/2022
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.11.1 Firefighters’ Emergency Operation Documentation No No Perform monthly fire service and document on log in machine room 10/18/2022
A17.1-1996 : Elevators 2.3 - Lighting and receptacles 101.5a Lighting Yes No Machine room lighting shall not be less than 200 lux/19fc at floor. 9/19/2023
A17.1-2016 : Elevators 1.17 - Standby power operation 2.27.2 Yes No Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator, annually. 5/29/2026
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Car Emergency System (Re-Inspection) Yes No Emergency lighting shall work. 5/29/2026
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Car Emergency System (Re-Inspection) Yes No Emergency lighting shall work.
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Repair emergency phone in car 6/3/2021