A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
emg phone not working
|
9/30/2020
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1(a)(3) Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
replace the backup battery for the emergency phone, the phone would not dial out with the 110 volt power off
|
2/9/2024
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1206.2b (Clean Machine Room)
|
|
|
do not store non elevator related items in the machine room
|
|
A17.1-2016 : Elevators
|
2.36 - Hydraulic Cylinders
|
8.11.3.1.2(x)
|
x
|
|
car settle4d onto the springs during 15 minute set test, did not move at all when the gate valve in the machine room was closed, repair or replace valve
|
5/12/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Inspection incomplete, a power supply went bad in the controller, elevator would not run until new part installed, need to test fire service to complete the test
|
5/12/2022
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
no current cirt displayed
|
5/12/2021
|