A17.1-2016 : Elevators
|
2.6 - Ventilation
|
2.7.9.2
|
x
|
|
mach room ventilation needs to be working
|
10/20/2025
|
|
A17.1-2016 : Elevators
|
2.6 - Ventilation
|
2.7.9.2
|
|
|
need ventilation control hooked up
|
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3.1.1 Phase I Emergency Recall Operation
|
x
|
x
|
no phase one fire serv key sw in hall
|
10/20/2025
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Emg. lt.an Bell not working
|
12/14/2018
|
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection)
|
x
|
|
elev would run to 4th floor on phase two fire serv
|
10/9/2025
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
current cirt not displayed
|
10/9/2025
|
|
MO Minimum : Elevators
|
(N) - Guide Rails
|
(N)1
|
x
|
|
rusted pit bracket holding guide rail in pit
|
10/20/2025
|
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Main hoisting ropes badly rouged, and undersized. Unit red tagged and removed from service.
|
2/28/2020
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)5
|
|
|
needd pit ladder installed pit over 4ft deep no ladder
|
10/9/2025
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
x
|
|
mach. room door locks need to be self locking
|
10/20/2025
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
mach. room doors are not self locking
|
|