Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys Yes No All fire recall keys in a single fire division shall be keyed alike. Mod changed lobby phase 1 key switch to a FEOK1. This requires all phase 2 key switches on cars 1-6 to be FEOK1's and the kitchen passenger phase 1 & 2. Re-inspection required
A17.1-1996 : Elevators 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) 8.4.10.1.2 - Protection not functioning Yes No Elevator shall move away from counterweight and park with the doors open when switch is activated. Re-inspection required 6/9/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Test incomplete, need to perform the following test to complete inspection: No load, full speed counterweight buffer testing. Re-inspection required 10/1/2024