ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2.6 Sump Pump Covers
|
|
|
Pit sump pump hole is not covered.
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
8.11.2.1.3(m)
|
|
|
Counterweights are compressing buffer in pit when car is at top landing. Shorten ropes to provide minimum runby of 6"
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
No maintenance records on site.
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.8 - Top emergency exit
|
8.11.2.1.3(l)
|
|
|
Emergency hatch shall be operable. Remove temporary weights from top of hatch.
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
Written maintenance control program shall be provided on site.
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2.6 Sump Pump Covers
|
|
|
Sump pump hole shall be covered.
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
8.11.2.1.3(m)
|
|
|
Counterweights are compressing buffer in pit when car is at the top landing. Hoist ropes need to be shortened to get minimum runby of 6".
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
No maintenance control program in the machine room
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.8 - Top emergency exit
|
8.11.2.1.3(l)
|
|
|
Emergency exit shall be operable, remove temporary weights from top of hatch.
|
4/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not work.
|
3/2/2021
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
Test incomplete. Car top still needs to be inspected
|
10/12/2021
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Provide testing on emergency power.
|
8/9/2024
|
A17.1-2016 : Elevators
|
4.12 - Standby power selection switch
|
8.6.4.19.7 (Re-Inspection)
|
x
|
|
Provide testing.
|
8/9/2024
|