ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.11.2.2.6 Fire Fighters Operation (Re-Inspection)
|
x
|
x
|
When on fire service with car running up, the call cancel slows car down. It then stops the car, but not at a landing and doors are able to be accessed and opened in the middle of the hoistway. Elevator Red Tagged.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.3 - Firefighters' service (A17.1-1984 through A17.1a-1988 and A17.3)
|
8.11.2.1.4(l)
|
x
|
x
|
When using the call cancel feature on Phase 2 fire service, it cancels the car call and stops the elevator on a low oil condition.
|
7/22/2019
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
6/19/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
The in car emergency telephone shall be operational on auxiliary power.
|
9/28/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
6/21/2023
|