MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A copy of the current state operating certificate shall be displayed in the machine room
|
5/20/2024
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
x
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a non-combustible frame with a clear protective vision plate over it
|
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
5/20/2024
|
|
A17.1-2016 : Elevators
|
2.14 - Code data plate
|
8.9
|
x
|
|
A data plate shall be provided indicating the code in effect at the time of the alteration and the applicable requirements of section 8.7.
|
|
|
A17.1-2016 : Elevators
|
2.3 - Lighting and receptacles
|
2.8.2
|
x
|
|
A duplex GFCI receptacle shall be provided in the machine room.
|
|
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.19.15 Emergency Communications
|
x
|
|
A visual indication on the same panel as the "PHONE" push button shall be provided to acknowledge that two-way communications link has been established.
|
|
|
A17.1-2016 : Elevators
|
2.4 - Machine space
|
8.6.4.8 Machine Room and Machinery Space
|
x
|
|
Pieces of the drop ceiling are missing in the machine room and shall be installed/replaced.
|
|
|
A17.1-2016 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
8.6.4.13.1(l)(Door Restrictor)
|
x
|
|
The car door shall be restricted from opening when in the closed position anywhere outside the unlocking zone.
|
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.7.2.16.4
|
x
|
|
The car shall run correctly on emergency power. The car ran up to verify the ability to light the load, but would not respond after first run.
|
|
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams)
|
x
|
|
The correct schematics shall be in the machine room
|
|
|
A17.1-2016 : Elevators
|
3.17 - Door and gate equipment
|
2.13
|
x
|
|
The door operator kinetic energy tag shall be filled out to indicate the minimum door closing times.
|
|
|
A17.1-2016 : Elevators
|
1.17 - Standby power operation
|
8.7.2.15.2
|
x
|
|
The illuminated signal for emergency power shall operate as required.
|
|
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.10.2.2.5(a)
|
x
|
|
The lighting in the pit shall provide an illumination of no less than 11 1X(10ft) at the pit floor.
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
The muffler leaks oil, repair.
|
5/20/2024
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.3
|
x
|
x
|
The new elevator controller is to be connected to the building security system. Once this is complete, a re-inspection shall be performed to verify it will be rendered inoperative when on fire service operation.
|
|
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.10.2.2.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
The two-way communication means within the car shall include a means to verify operablility of the line meeting the requirements of 2.27.1.1.6. If means other than a telephone line are used for two-way communications, similar verification of this equivlent means shall be performed.
|
|