Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Ceiling light guards are of the egg crate type. The bulbs must be protected by solid light guards or tubes in case of a shatter. 3/18/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams 120V car top fan wired with a cord and plug to a screw-in. adapter in cartop light socket--wire correctly 2/13/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need a maintenance control program on site 3/30/2021
MO Minimum : Elevators (H) - Machine Rooms (H)1 Patch hole in machine roon ceiling 5/3/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) x Overspeed valve is not sealed and must be tested within 90 days or less 2/8/2023