Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Car gate and hoistway doors, as well as governor pullout/pullthru, and governor switch and jaw were the only tests witnessed on 2/21/2020. All other tests required by MO CSR 40-5.090 have yet to be performed and shall be rescheduled. Other deficiencies may be noted after testing is complete. 6/5/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Car gate and hoistway doors, as well as governor pullout/pullthru, and governor switch and jaw were the only tests witnessed on 2/21/2020. All other tests required by MO CSR 40-5.090 have yet to be performed and shall be rescheduled to complete category 5 test and periodic inspection. Other deficiencies may be noted after testing is complete. 1/25/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting x The cab lighting shall be operational and not less then 5fc. Elevator Red Tagged due to alarm bell and cab lighting both not working. There is no phone or intercom. 6/5/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x x The alarm bell shall be operational. Elevator Red Tagged due to alarm bell and cab lighting both not working. There is no phone or intercom. 6/5/2020
MO Minimum : Elevators (H) - Machine Rooms (H)1 The lighting in the stairway going up to the machine room shall be operational.
MO Minimum : Elevators (H) - Machine Rooms (H)1 The lighting in the stairway going up to the machine room shall be operational.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room shall be enclosed and accessible only to authorized personnel.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room shall be enclosed and accessible only to authorized personnel.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room shall have permanent lighting of not less than 10 fc.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room shall have permanent lighting of not less than 10 fc.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide a current tested ABC fire extinguisher in the machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide a current tested ABC fire extinguisher in the machine room.