Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. 4/1/2020
MO Minimum : Elevators (I) - Pits (I)1 Water & sludge in pit shall be removed and pit cleaned 4/28/2022
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be kept clean & dry. Pit floor is covered in water & sludge 4/10/2024
MO Minimum : Elevators (I) - Pits (I)1 The elevator pit floor is covered in water and debris. The elevator pit shall be kept clean and dry 4/21/2025
A17.1-2016 : Elevators 2.35 - Supply Line and Shutoff Valve 8.11.3.1.2(w) A shutoff valve shall be installed adjacent to pump unit in machine room 4/28/2022