Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11 Periodic Inspection and Test. x 8.11.3.4.1 Unable to perform CAT 5 buffer tests 1/17/2022
A17.1-2016 : Elevators 2.43 - Emergency Brake, Ascending Car Overspeed, and Unintended Car Movement Protection 8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake x Unable to perform Category 1 Unintended Movement Test. Unintended car movement shall be subjected to tests with no load in the car at the slowest operating (inspection) speed in the up direction. 2/21/2023
A17.1-2016 : Elevators 3.20 - Governor rope 2.18.5 Governor Rope showing rouge, diameter is below minimum allowable value, passed cat 5 tests 5/31/2022
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.20 - Governor rope 8.11.2.1.3(z) Governor Rope showing rouge, diameter is below minimum allowable value 5/31/2022