MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
machroom door lock if defeatable need to change to undefeatable
|
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
phone was answerwd but person on other end couldnt tell me where i was located. voice quility was very bad couldnt understand conversation
|
|
A17.1-2016 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
8.6.4.13.1(l)(Door Restrictor)
|
x
|
|
door restrictor didnt work
|
|
A17.1-2016 : Elevators
|
2.36 - Hydraulic Cylinders
|
8.6.5.5.2 Collection of Oil Leakage
|
|
|
remove hoses from cyl. heads back to tanks
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Backup light and bell inop.
|
1/11/2024
|