MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Determine cause of water running down back of hoistway to pit and repair
|
2/26/2025
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Discontinue storage of non-elevator related items in the machine room.
|
2/26/2025
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Emergency light stays on, power supply needs to be replaced. Re-inspection required
|
4/5/2024
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)9
|
|
|
There is no protection found on this elevator power supply to prevent accidental motor phase reversal. Without a motor phase reversal device, there is a greater potential for equipment damage when a power loss occurs. Provide a motor phase reversal device on the elevator power supply.
|
3/11/2021
|