Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.31 - Relief Valves 8.11.3.1.2(n) Relief pressure approx 100 psi below documented reading, repair. 11/10/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.39 - Low Oil Protection 3.26.9 Low Oil Protection (Re-Inspection) Repair low oil timing circuit. 11/10/2020