Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light in car shall work. Re-inspection required 9/27/2022
MO Minimum : Elevators (F) - Electrical Switches (F)1 x In car emergency stop switch shall work. Re-inspection required 9/27/2022
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal x In car Fire service Phase I recall light shall work. Re-inspection required 9/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x Car gate reversing edge shall work. Re-inspection required 9/27/2022
MO Minimum : Elevators (A) - Hoistways (A)3 Adjust hoistway door gap at second floor when car is away from floor 9/28/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP shall be kept in the machine room for each elevator 9/28/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Car failed 15 minute stand test, tech determined that it was back flowing through the valve. 4/17/2023