Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing 8.6.5.16.5 OSV NOT SEALED TEST DUE IN 2021 7/5/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP shall be kept in the machine room for each elevator 5/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP shall be kept in the machine room for each elevator 7/5/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current copy of the state operating certificate shall be displayed in the elevator machine room 5/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Alarm bell and light are inoperative. Repair. 12/5/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.5 - Car lighting and receptacles 2.14.7.1.1 Not less than two lamps At least two light fixtures are required for proper illumination inside the elevator cab, only one light fixture was in operation on the day of inspection. Repair fixture.
MO Minimum : Elevators (S) - Fire Service (S)1 x x Cab fire service inoperative on recall, repair. Reinspect by 1/5/2020 2/27/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x Cab fire service light inoperative on recall. Repair 12/5/2019
conversion conversion conversion - reinspect x Cab fire service light on when car not on recall. Conversly, light extingushes when car is on recall need reapair 4/24/2019
MO Minimum : Elevators (S) - Fire Service (S)1 x x Cab fireman's jewel visual signal inoperative. Repair within 30 days. 6/9/2020
MO Minimum : Elevators (I) - Pits (I)1 Clean pit. 5/24/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency alarm in car is not working, may need battery replaced. Re-inspection required 9/28/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency alarm in car shall be made operable. Re-inspection required 5/20/2022
MO Minimum : Elevators (A) - Hoistways (A)5 Left side lower panel door guide shoe is broken. Repair 7/5/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) x OSV is not sealed. Noted in last inspection. Perform required testing, seal & tag within 90 days. Re-inspection required 5/20/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current operating certificate. 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP. 7/5/2023
MO Minimum : Elevators (C) - Car Enclosure: Freight (C)1 Remove mounted fire extinguisher from inside the elevator. See ‘96 204.3a 5/24/2023
conversion conversion n/a Replace seal between head and cylinder flanges. Seal leaks during pressure relief test 4/24/2019
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)1 Replace seal between head cylinder flanges. Seal leaks during pressure relief test. 7/5/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.8 - Pipes, wiring, and ducts 2.8.2 (Re-Inspection) x The sprinkler head in the elevator machine space is required to have a heat detector to activate the shunt trip disconnect before the application of water. Heat detectors shall be installed within 2’ of each sprinkler head to activate the shunt trip disconnect. 10/9/2024