Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) Hoistway door safety access toggle switches inoperative on all floors. 7/5/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in elevator machine room 5/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A copy of the MCP shall be kept in the machine room for each elevator 5/22/2023
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) Hoistway door safety access toggle switches shall be operable at all landings 5/22/2023
A17.1-1996 : Elevators 1.1 - Door Re-opening device 1001.2(a)(1) Repair inoperable gate reversing edge on front car gate. Re-inspection required 5/22/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate. 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing hoistway/car door/gate pull straps as needed. 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing cotter pin on car door rods (2). 7/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Replace missing hoistway doorlock interlock cover at 2nd floor. 7/5/2023
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room lights were flickering during testing, repair as needed. 7/5/2023
MO Minimum : Elevators (I) - Pits (I)1 Pit needs to be cleaned 9/24/2024
A17.1-1996 : Elevators 3.2 - Car top light and outlet 204.7 Light on cartop shall work, needs repaired 9/24/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Hoistway door safety access toggle switches shall be operable at all landings 9/24/2024
conversion conversion n/a Clean pit 7/5/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 1206.2a (Pits and Hoistways) Clean pit 7/5/2023
A17.1-1996 : Elevators 1.7 - Car door or gate 204.6 Front and rear gate off track. Repair 7/5/2023
A17.1-1996 : Elevators 3.17 - Door and gate equipment 1001.2(c)(23) Hoistway door safety access toggle switches inopertive on all floors. 7/5/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency light and alarm inoperative on battery back-up. 6/9/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x Need to repair inoperable gate reversing edge on front car gate. Re-inspection required 9/3/2024