Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) x x The relating of car and hoistway doors is not operating properly. Take corrective action as needed. 6/1/2023
A17.1-1996 : Elevators 1.13 - Emergency exit 1001.2(a)(13) Properly secure car top exit.
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x An in car emergency telephone is required. 11/18/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x There shall be an emergency telephone located in the elevator car. 7/3/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x An in car emergency telephone is required. (Repeat violation) 10/13/2020
A17.1-1996 : Elevators 1.7 - Car door or gate 204.4 x x Car interlocking devices not operating properly. Car runs with the doors open. Elevator has been red tagged until repairs are made. 6/1/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The test is incomplete. The following testing items remain: pull out/pull thru of governor, governor switch and jaw, governor full load test of car safeties, buffer and counterweight buffer test. 11/23/2021
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) The machine room door shall be self-closing and self-locking. 5/12/2023
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) The machine room door shall be self-locking and self-closing. (Repeat Violation) 5/12/2023
A17.1-1996 : Elevators 2.1 - Access to machine space 1001.2(b)(1) The machine room door shall be self-locking and self-closing.
A17.1-2016 : Elevators 2.17 - Drive machine brake 8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake x The pads on the rope gripper are worn down below tolerance. 3/28/2023
A17.1-2016 : Elevators 2.17 - Drive machine brake 8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake x x Pads on rope gripper are worn down below tolerance. (2nd Notice) 6/1/2023
A17.1-1996 : Elevators 2.17 - Drive machine brake 1001.2(b)(15) x x The pads on the rope gripper are worn down below tolerance. 11/23/2021
A17.1-1996 : Elevators 2.3 - Housekeeping n/a Clean the car top. 5/12/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 10/17/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing.
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.2b (Clean Machine Room) The machine room shall be cleaned. 5/12/2023
A17.1-1996 : Elevators 3.12 - Pipes, wiring, and ducts 1001.2(c)(18) Install covers on electrical boxes in hoistway.
A17.1-1996 : Elevators 3.12 - Pipes, wiring, and ducts 1001.2(c)(18) Install covers on electrical boxes in the hoistway. 5/12/2023
A17.1-1996 : Elevators 3.12 - Pipes, wiring, and ducts 1001.2(c)(18) Install covers on electrical boxes in hoistway. (Repeat Violation) 5/12/2023
A17.1-1996 : Elevators 3.2 - Car top light and outlet 1001.2(c)(2) The car top lighting shall be operational. 5/12/2023
A17.1-1996 : Elevators 3.8 - Top emergency exit 1001.2(c)(12) Properly secure car top exit. 5/12/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit shall be kept dry. 5/12/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit shall be kept clean and dry. 5/12/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Pit has an excessive amount of water in it. Water shall be removed from the pit and the pit shall be kept clean and dry.