MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
The test is incomplete. The following testing items remain: pull out/pull thru of governor, governor switch and jaw, governor full load test of car safeties, buffer and counterweight buffer test.
|
11/23/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Door Systems 8.6.4.13 (Re-Inspection)
|
x
|
x
|
The relating of car and hoistway doors is not operating properly. Take corrective action as needed.
|
6/1/2023
|
A17.1-1996 : Elevators
|
1.13 - Emergency exit
|
1001.2(a)(13)
|
|
|
Properly secure car top exit.
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
An in car emergency telephone is required.
|
11/18/2021
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
There shall be an emergency telephone located in the elevator car.
|
7/3/2019
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
An in car emergency telephone is required. (Repeat violation)
|
10/13/2020
|
A17.1-1996 : Elevators
|
2.1 - Access to machine space
|
1001.2(b)(1)
|
|
|
The machine room door shall be self-closing and self-locking.
|
5/12/2023
|
A17.1-1996 : Elevators
|
2.1 - Access to machine space
|
1001.2(b)(1)
|
|
|
The machine room door shall be self-locking and self-closing. (Repeat Violation)
|
5/12/2023
|
A17.1-1996 : Elevators
|
2.1 - Access to machine space
|
1001.2(b)(1)
|
|
|
The machine room door shall be self-locking and self-closing.
|
|
A17.1-1996 : Elevators
|
2.17 - Drive machine brake
|
1001.2(b)(15)
|
x
|
x
|
The pads on the rope gripper are worn down below tolerance.
|
11/23/2021
|
A17.1-1996 : Elevators
|
3.8 - Top emergency exit
|
1001.2(c)(12)
|
|
|
Properly secure car top exit.
|
5/12/2023
|
A17.1-1996 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
1001.2(c)(18)
|
|
|
Install covers on electrical boxes in hoistway. (Repeat Violation)
|
5/12/2023
|
A17.1-1996 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
1001.2(c)(18)
|
|
|
Install covers on electrical boxes in the hoistway.
|
5/12/2023
|
A17.1-1996 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
1001.2(c)(18)
|
|
|
Install covers on electrical boxes in hoistway.
|
|
A17.1-1996 : Elevators
|
3.2 - Car top light and outlet
|
1001.2(c)(2)
|
|
|
The car top lighting shall be operational.
|
5/12/2023
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1
|
|
|
Pit has an excessive amount of water in it. Water shall be removed from the pit and the pit shall be kept clean and dry.
|
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit shall be kept dry.
|
5/12/2023
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
106.1e Illumination of Pits
|
|
|
The pit shall be kept clean and dry.
|
5/12/2023
|
A17.1-1996 : Elevators
|
2.5 - Housekeeping
|
1206.2b (Clean Machine Room)
|
|
|
The machine room shall be cleaned.
|
5/12/2023
|
A17.1-1996 : Elevators
|
1.7 - Car door or gate
|
204.4
|
x
|
x
|
Car interlocking devices not operating properly. Car runs with the doors open. Elevator has been red tagged until repairs are made.
|
6/1/2023
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing.
|
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
|
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022)
|
10/17/2023
|
A17.1-2016 : Elevators
|
2.17 - Drive machine brake
|
8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake
|
x
|
x
|
Pads on rope gripper are worn down below tolerance. (2nd Notice)
|
6/1/2023
|
A17.1-2016 : Elevators
|
2.17 - Drive machine brake
|
8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake
|
x
|
|
The pads on the rope gripper are worn down below tolerance.
|
3/28/2023
|
A17.1-1996 : Elevators
|
2.3 - Housekeeping
|
n/a
|
|
|
Clean the car top.
|
5/12/2023
|