Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) x Restricted opening inoperative, repair. 9/30/2019
MO Minimum : Elevators (S) - Fire Service (S)1 x x No audible signal on Phase I return. 1/30/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) x Repair car door restrictor. 1/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Provide pit bucket for oil collection. 9/17/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) x Door restrictor works intermittently. Repair or replace. 10/1/2020
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8 x Provide feeder location on main line disconnect (NEC620.51) 7/31/2023
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 2.8 x Provide feeder location on 110v. disconnect(NEC620.51). 7/31/2023
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.8 x Provide pit GFCI outlet to work properly (NEC620). 7/31/2023
A17.1-2016 : Elevators 2.6 - Ventilation 2.7.9.2 x Provide existing climate control in the elevator machine room to work properly. 7/31/2023
A17.1-2016 : Elevators 2.4 - Machine space 2.7.1 x Seal all machine room wall and ceiling penetrations. 7/31/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 x Existing pipes over the elevator equipment are leaking repair as needed. 7/31/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 x Existing pipes to be covered to prevent future leaks/condensation from the elevator equipment. 7/31/2023
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device x x Provide Phase I emergency recall operations by Fire Alarm Initiating Devices (FAID) 7/31/2023