Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Cab phone inoperative. 1/22/2020
A17.1-1996 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 1206.2(c) Clean car top 3/1/2022
A17.1-1996 : Elevators 2.5 - Housekeeping 1206.9 Clean cartop and machine room after repairs are made 1/21/2020
A17.1-1996 : Elevators 3.19 - Guide rails fastening and equipment 1206.1d Clean lint build-up from main and counterweight guide rails. 1/21/2020
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Clean machine room 3/1/2022
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits Clean pit 3/1/2022
MO Minimum : Elevators (I) - Pits (I)1 Clean trash out of elevator pit 1/8/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Door restrictor is missing parts, needs repaired. Re-inspection required 1/8/2024
A17.1-1996 : Elevators 3.6 - Final and emergency terminal stopping devices 1001.2(c)(8) x x Final limit cannot be actuated due to counterweight mashing the buffer completely. 11/10/2018
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys x Fire service keys for all elevators in one building shall be keyed alike. Re-inspection required 1/8/2024
A17.1-1996 : Elevators 2.25 - Traction sheaves 1202.14 x x Traction drive sheave shows excessive wear. Needs to be repaired or replaced. 11/10/2018