Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation No No PROVIDE A WORKING PHASE 1 FIRE SERVICE JEWEL
conversion conversion conversion - reinspect Yes No Permit needs to be obtained from the state for replacement of hydraulic pumping unit, which has already been replaced. 1/30/2019
conversion conversion conversion - red tag Yes Yes Replaced pumping unit needs acceptance test performed and witnessed by a licensed inspector.. 1/30/2019
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal Yes No No visual signal during fire recall 1/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) Yes Yes EMERGENCY LIGHT NOT WORKING 7/22/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit No No Remove standing water and oil from pit floor 1/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.7.2 Periodic Test Record (Test Tags) No No Attach metal test tag for periodic test 1/15/2026
MO Minimum : Elevators (H) - Machine Rooms (H)8 No No Install cover on starter panel in machine room 1/15/2026
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys No No Firefighter key needs to be kept on site 1/15/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room access door needs to be self-locking. 1/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces No No Remove non-elevator related material and rags from machine room floor. 1/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams No No Install front cover on motor controller enclosure. 1/15/2026
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys No No Provide firefighter key on site 1/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation No No Test and log firefighter operation monthly 1/15/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Post In Case of Fire Do Not Use Elevator signage next to corridor call station 1/15/2026
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal No No No visual signal during fire recall operation 2/11/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No Maintenance record log not up to date 2/11/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No State operating certificate not displayed 2/11/2026
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal No No Phase 1 jewel on COP not working. 2/11/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts No No Provide a cover for starter panel in machine room. 2/11/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance No No REPACK JACK AND CLEAN OIL OVERFLOW FROM PIT 2/11/2026
MO Minimum : Elevators (I) - Pits (I)2 No No FASTEN SPRING STANDS DOWN TO PIT CHANNEL 2/11/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams No No INSTALL COVER ON STARTER PANEL 2/11/2026
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal No No PROVIDE A WORKING IN CAR FIRE SERVICE JEWEL 2/11/2026
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No PROVIDE A WORKING EMERGENCY LIGHT & ALARM 2/11/2026