Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Permit needs to be obtained from the state for replacement of hydraulic pumping unit, which has already been replaced. 1/30/2019
conversion conversion conversion - red tag x x Replaced pumping unit needs acceptance test performed and witnessed by a licensed inspector.. 1/30/2019
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-locking.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Remove non-elevator related material and rags from machine room floor.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams Install front cover on motor controller enclosure.
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys Provide firefighter key on site
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.11.1 Firefighters' Emergency Operation & Documentation Test and log firefighter operation monthly
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Post In Case of Fire Do Not Use Elevator signage next to corridor call station
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal x No visual signal during fire recall 1/13/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Remove standing water and oil from pit floor
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.7.2 Periodic Test Record (Test Tags) Attach metal test tag for periodic test
MO Minimum : Elevators (H) - Machine Rooms (H)8 Install cover on starter panel in machine room
MO Minimum : Elevators (S) - Fire Service 211.8 Switch Keys Firefighter key needs to be kept on site
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal No visual signal during fire recall operation
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Maintenance record log not up to date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate not displayed
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal Phase 1 jewel on COP not working.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Provide a cover for starter panel in machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x x EMERGENCY LIGHT NOT WORKING
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance REPACK JACK AND CLEAN OIL OVERFLOW FROM PIT
MO Minimum : Elevators (I) - Pits (I)2 FASTEN SPRING STANDS DOWN TO PIT CHANNEL
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams INSTALL COVER ON STARTER PANEL
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal PROVIDE A WORKING IN CAR FIRE SERVICE JEWEL