Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate A current state operating certificate shall be obtained and displayed. Note: The displayed certificate expired 7/1/18.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.4 Escalator Combplates x Replace broken comb plate sections.
conversion conversion n/a Replace broken comb plate, top landing.
conversion conversion n/a Replace broken tread plate
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x Upper and lower demarcation lights not working 12/7/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Upper and lower walk-on deck switches are taped/defeated. Repair/adjust.
A17.1-1996 : Escalators 7.15 - Balustrades 802.3 Upper balustrades (left and right at upper curve) shall be repaired to provide a smooth seam between panels. Currently seam is very proud or protruding from the surface.