Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light does not illuminate, and emergency bell does not operate without normal power. 10/13/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light and bell do not operate 3/15/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Door reopening device is connected to the car lighting circuit. Car lighting shall be on a dedicated circuit. 5/11/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Remove standing water in elevator pit. Sump pump is not operating. 5/11/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-locking and non-defeatable 5/11/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room access door needs to be self-closing 5/11/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Replace missing cieling tile in machine room. Cables not related to elevator equipment are hanging down into machine room where cieling tile is missing 5/11/2023
MO Minimum : Elevators (I) - Pits (I)8 Provide a cover for the sump hole in the pit. cover shall be of non-flammable material, allow water to flow through it, and withstand 250 pounds of weight 9/4/2024