Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 11/30/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 11/30/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No An oil scavenger line shall be installed on the jack, with an associated oil collection container. 11/14/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No Car ride was rough and noisy. Take corrective action as needed. 11/21/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No The fire extinguisher in elevator machine room is expired and shall be serviced or replaced. 6/18/2019
MO Minimum : Elevators (I) - Pits (I)1 No No The pit contains excessive oil and debris and shall be cleaned. 11/14/2018
MO Minimum : Elevators (I) - Pits (I)1 No No The pit shall be kept clean and dry. 11/30/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No The presence of an overspeed valve has been confirmed, along with an installation date of 2018. The overspeed valve shall be scheduled for a category 5 test as required by A17.1 2016 – 8.6.5.16.5, 8.11.3.1.5(q), on or before the 2023 annual inspection due date per the MO AHJ. 11/30/2023