Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.10 Acceptance Inspection and Test x This elevator is connected to an emergency generator and shall be tested while operating on the generator. Generator is currently out of service and parts are on order. All other acceptance testing has passed.
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Replace hoist cables due to diameter reduction and breakage. 30-day compliance or red tagged. 6/18/2019
MO Minimum : Elevators (S) - Fire Service (S)1 x Car door shall not open automatically, only with constant pressure on Phase II 6/15/2021
MO Minimum : Elevators (S) - Fire Service (S)1 x x Repair fire recall Phase I. Door automatically opens at floor and call cancel doesn't cancel call. 8/31/2021
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Replace the governor cable that is about to break in two places. 8/31/2021
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Repair fire recall phase 2. Door auto opens at floor and call cancel does not work 11/2/2022
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Replace governor cable. Cable about to break in two 11/2/2022
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Provide proper working Phase I operations, door failed to open upon recall.(‘96. 211.3) 6/6/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Provide existing Phase II operations to work properly. Went to lowest floor, doors opened automatically.(‘96. 211.3) 6/6/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide existing pit light to work. 9/4/2024
A17.1-2016 : Elevators 2.11 - Disconnecting Means and Control 2.26.4.1 x Machine room disconnects shall have feed location labels. 5/15/2025
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Runby (Re-Inspect) x Suspension ropes to be shortened to allow for proper "runby". Currently only 4.5" of runby and shall be between 6" - 12". 5/15/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.10 Acceptance Inspection and Test x FAID shall be tested. 5/15/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x This elevator is connected to an emergency generator and shall be tested while operating on the generator. Generator is currently out of service and parts are on order. 5/15/2025