Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Hold position phase 2 fire service 12/4/2018
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)12 (Door open zones) x Disabled car door restrictor. 1/14/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV not sealed. Perform OSV test on or before next annual inspection. 10/25/2022
MO Minimum : Elevators (H) - Machine Rooms (H)9 Reverse phase relay needs to be installed to prevent reverse operation of the motor or loss of phase. 10/25/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates The signage for “In Case of Fire Use Stairs” is missing. Install signage that conforms to the building code this elevator was installed to meet. 10/25/2022
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage There is no fireman’s emergency service phase I instruction signage adjacent to the keyed switch at the primary egress floor, as required. 10/25/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The battery back–up lowering device was tested and did not operate as designed, the elevator failed to return to a lower floor and open its doors. Repair the device to operate as it is designed. 10/25/2022
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x The battery back–up lowering device was tested and did not operate as designed, the elevator failed to return to a lower floor and open its doors. Repair the device to operate as it is designed. 9/19/2024