Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors The car sill is not level with the newer floor, creating a tripping hazard. 2/3/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting The cab lighting shall be guarded to prevent accidental breakage or contact. 2/3/2020
MO Minimum : Elevators (A) - Hoistways (A)16 Coax cable and ground wire in the hoistway shall be removed. 2/3/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit lighting shall be operational. 2/3/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post the current state operating certificate. 2/3/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-locking. 2/3/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods A maintenance log shall be kept on site. 2/3/2020
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log A monthly log of fire service testing shall be kept on site. 2/3/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation The muffler is leaking and shall be repaired or replaced. 2/3/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Replace the Phase 1 & Phase 2 bezel in the car and hallway. 2/3/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers The fire extinguisher in the elevator machine room is expired and shall be serviced or replaced with a current tested ABC type extinguisher. 6/30/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO state operating certificate shall be displayed in the elevator machine room. 6/30/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room shall be cleaned. 6/30/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x The door re-opening device is not work as it should. Repair as needed. 3/30/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11.1.4(a) Elevators Placed in Inactive Status x x Elevator is not running and requires many repairs. Unit is being placed out of service, inactive status. Car landed, made inoperable and locked out. 10/19/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 x Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. The gas line running in close proximity to the elevator equipment in the machine room shall be guttered or guarded. 1/4/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 x The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. The lock-set on the door is not self-locking 1/4/2024
MO Minimum : Elevators (H) - Machine Rooms (H)8 x Feeder locations for the main and lighting branch circuit shall be marked on the disconnects. 1/4/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Per Wentzville Fire Marshall Chris Cuddihee, the designated floor for main firefighters service recall shall be changed to the bottom landing, and the secondary recall to the second landing. This will require moving the phase one key-switch, instructions, and visual alert to the bottom landing. The egress floor signage inside the car and on the door frames, and the telephone monitor visual, audible, and key-switch shall also be moved/changed to make the bottom landing the main floor of egress. After this work is complete, a re-inspection shall be performed and all the initiating devices re-tested. 1/4/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone is not working on battery back up. Take corrective action and re-test. 11/6/2024