Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(c)(2) Must Preform and Doc. Monthly fire service testing. 8.6.2.1(c)(2) 12/6/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Must Provide and Maintain all required MCP Documentation. 12/6/2023
A17.1-2016 : Elevators 1.1 - Door Reopening Device 8.6.4.13.1(c) Must replace/repair broken door re-opening device Rubber boot to maintain proper operation. 8.6.4.13.1(c) 11/15/2023
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits Pit must be Kept Free of Debris. 12/6/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Must make emergency alarm operable. 8.6.4.15 4/15/2024
A17.1-2016 : Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Car Emergency System (Re-Inspection) x Must make Emergency Light operable. 8.6.4.15 4/15/2024
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 8.6.4.19.6 x Must test Fire service for proper operation (at the time of inspection Rear door lock was not function properly could not test Fire service)Re-inspection required once repair is made. 8..4.19. 4/15/2024