Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.17 - Standby power operation 3.26.10 Yes No Auxiliary battery lowering device (emergency rescue unit) is not wired correctly. When the mainline disconnect is turned off, the car automatically goes into auxiliary battery lowering operation causing an unsafe condition for elevator personnel. Wire auxiliary battery lowering device to not go into emergency rescue mode when the mainline disconnect is moved to the off position. Re-inspection required
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) Yes No car door restrictor shall work 6/27/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 3.26.10 Yes No Auxiliary Power Lowering Operation needs tested upon installation of aux contacts in disconnect. 3/1/2026